H2SW · Bell Textron Canada Limited

206L / 206B / 407

Revision change summary 55 → 56

Generated 2026-11-05T19:40:58.739Z

AT A GLANCE

Revision 56 changes the Model 407 maximum power-off rotor speed from 422 rpm to 442 rpm. The associated dual-tachometer reading remains 107%. No other substantive changes were identified in the supplied documents.

01

Model 407 maximum power-off rotor speed changed

Model 407, power-off rotor operation. The edited table states no serial-number or configuration-specific restriction.

The Model 407 rotor-limit table changes the maximum power-off speed from 422 rpm to 442 rpm, a 20 rpm increase. The associated “Dual Tach Reading 107%” is unchanged, as are the minimum power-off speed and both power-on limits. The documents do not state whether this edit corrects the printed rpm value or reflects a revised operating limit.

Check the FAA source documents

Revision 55 · 11/19/2025
Open FAA DRS ↗ · Saved source PDF ↗

Revision 56 · 10/30/2026
Open FAA DRS ↗ · Saved source PDF ↗